Products
Contact Us
- Contact Person : Mr. Jianxin Wang
- Company Name : Yangzhou Goldenwell Medical Devices Factory
- Tel : 86-514-87210778
- Fax : 86-514-87210448
- Address : Jiangsu,Yangzhou,No.16 Tengfei Road, Dinggou Industrial Park of Jiangdu District,Yangzhou City, Jiangsu Province, P.R. China
- Country/Region : China
- Zip : 225235
Portable External Defibrillator
Product Detailed
Related Categories:Agricultural Product Stock
HD-9000A Features*Monophasic Defibrillator*Non-synchronizer:outlife difibrillator*Energy:0,3,5,7,10,20,30,50,100,200,300,360 joule*Charging time: At 360J less than 10 sec*Paddle options: Reusable external adult and pediatric paddles*Operates from the mains (AC) and with its internal Lead-acid batteryHD-8000AFeatures*Biphasic Defibrillator*Non-synchronizer:outlife difibrillator*Energy:0,3,5,7,10,20,30,50,100,200,300,360 joule*Charging time: At 360J less than 10 sec*Paddle options: Reusable external adult and pediatric paddles*Operates from the mains (AC) and with its internal Lead-acid batteryHD-9000B Features*Monophasic DefibrillatorECG:*ECG lead: Ⅰ,Ⅱ,Ⅲ, a VR, a VL, a VF, V1-V6*S-T segment analysis: –2.0-2.0mv*Protection: withstand 4000v AV/50HZ voltage in isolation and work against electrosurgical interence and defibrillation.*ECG lead/cable: general lead/cable for adult, pediatric and neonatal patientsNIBP:*Method: automatic oscillation*Working mode: manual/automatic*Measurement: adult: 10-250mmHgpediatric: 10-200mmHg*Rabge: neonatal: 10-135mmHgTEMP:*Measurement range: 20-45℃*Resoluion: 0.1℃SpO2:*Display: SpO2 value, pulse histongram, waveform, pulse*Range: 0-99% for adult, pediatric and neonatal patients*Probe: stand: adult finger clip *Optional: pediatric Y-type clip and neonatal wrapPulse:*Pulse range: 0-300bpm*Pulse accuracy: ±2bpmDefibrillator:*Synchronous and Asynchronous: outlife defibrillator*Energy: 0, 20, 50,100,160,250,300,360 joule*Charging time: at 360J less than 10sec*Paddle options: reusable external adult and pediatric paddles *Paddle options: operates from the mains (AC) and with internal Lead-acid battery10.4''TFT displayHD-8000BFeatures*Biphasic DefibrillatorECG:*ECG lead: Ⅰ,Ⅱ,Ⅲ, a VR, a VL, a VF, V1-V6*S-T segment analysis: –2.0-2.0mv*Protection: withstand 4000v AV/50HZ voltage in isolation and work against electrosurgical interence and defibrillation.*ECG lead/cable: general lead/cable for adult, pediatric and neonatal patientsNIBP:*Method: automatic oscillation*Working mode: manual/automatic*Measurement: adult: 10-250mmHgpediatric: 10-200mmHg*Rabge: neonatal: 10-135mmHgTEMP:*Measurement range: 20-45℃*Resoluion: 0.1℃SpO2:*Display: SpO2 value, pulse histongram, waveform, pulse*Range: 0-99% for adult, pediatric and neonatal patients*Probe: stand: adult finger clip *Optional: pediatric Y-type clip and neonatal wrapPulse:*Pulse range: 0-300bpm*Pulse accuracy: ±2bpmDefibrillator:*Synchronous and Asynchronous: outlife defibrillator*Energy: 0, 20, 50,100,160,250,300,360 joule*Charging time: at 360J less than 10sec*Paddle options: reusable external adult and pediatric paddles *Paddle options: operates from the mains (AC) and with internal Lead-acid battery10.4''TFT displayHD-9000CFeaturesECG:*ECG lead: Ⅰ,Ⅱ,Ⅲ, aVR, aVL, aVF, V1-V6NIBP:*Method: automatic oscillation*Working mode: manual/automatic*Measurement: adult: 10-250mmHgpediatric: 10-200mmHg*Rabge: neonatal: 10-135mmHgTEMP:*Measurement range: 20-45℃SpO2:*Display: SpO2 value, pulse histongram, waveform, pulsePulse:*Pulse range: 0~300bpm Pulse accuracy: ±2bpmDefibrillator:(1) Defibrillator type: Manual, Synchronized, Asynchronized, (2) Out put waveform: Monophasic (3) Energy accuracy: ∠+1% (4) Energy selection: 0,3,5,7,10,20,30,50,100,200,300,360 joule(nominal at a resistance of 50)(5) Charging time: Maximum 10 seconds to 360 Joules(6)Standard Adult/Pediatric Paddles: Reusable external adult paddles(pediatric paddles integrated)7''TFT displayHD-8000CFeaturesECG:*ECG lead: Ⅰ,Ⅱ,Ⅲ, aVR, aVL, aVF, V1-V6NIBP:*Method: automatic oscillation*Working mode: manual/automatic*Measurement: adult: 10-250mmHgpediatric: 10-200mmHg*Rabge: neonatal: 10-135mmHgTEMP:*Measurement range: 20-45℃SpO2:*Display: SpO2 value, pulse histongram, waveform, pulsePulse:*Pulse range: 0~300bpm Pulse accuracy: ±2bpmDefibrillator:(1) Defibrillator type: Manual, Synchronized, Asynchronized, (2) Out put waveform: Biphasic (3) Energy accuracy ∠+1% (4) Energy selection 0,3,5,7,10,20,30,50,100,200,300,360 joule(nominal at a resistance of 50)(5) Charging time: Maximum 10 seconds to 360 Joules(6)Standard Adult/Pediatric Paddles: Reusable external adult paddles(pediatric paddles integrated)7''TFT displayHD-9000DFeaturesECG:*ECG lead: Ⅰ,Ⅱ,Ⅲ, aVR, aVL, aVF, V1-V6*Protegtion: withstand 4000v AV/50HZ voltage in isolation and work against electrosurgical interence and defibrillation.*ECG lead/cable: general lead/cable for adult, pediatric and neonatal patientsDefibrillator:(1) Defibrillator type: Manual, Synchronized, Asynchronized, (2) Out put waveform: Monophasic (3) Energy accuracy: ∠+1% (4) Energy selection: 0,3,5,7,10,20,30,50,100,200,300,360 joule(nominal at a resistance of 50)(5)Charging time :Maximum 8 seconds to 360 Joules(6)Standard Adult/Pediatric Paddles: Reusable extermal adult paddles(pediatric paddles integrated)7''TFT displayHD-8000DFeaturesECG:*ECG lead: Ⅰ,Ⅱ,Ⅲ, aVR, aVL, aVF, V1-V6*Protegtion: withstand 4000v AV/50HZ voltage in isolation and work against electrosurgical interence and defibrillation.*ECG lead/cable: general lead/cable for adult, pediatric and neonatal patientsDefibrillator:(1) Defibrillator type: Manual, Synchronized, Asynchronized, (2) Out put waveform: Biphasic (3) Energy accuracy: ∠+1% (4) Energy selection: 0,3,5,7,10,20,30,50,100,200,300,360 joule(nominal at a resistance of 50)(5) Charging time: Maximum 8 seconds to 360 Joules(6)Standard Adult/Pediatric Paddles: Reusable extermal adult paddles(pediatric paddles integrated)7''TFT display
Other products